Peri-Mitral Atrial Tachycardia Following Transcatheter Aortic Valve Replacement

  • Teikyo University

研究成果: ジャーナルへの寄稿 › 記事 › 査読

抄録

Transcatheter aortic valve replacement (TAVR) is commonly used to treat severe aortic stenosis. Although atrial fibrillation and conduction disturbances are well-known complications, peri-mitral atrial tachycardia (PMT) post-TAVR is less frequently reported. A 75-year-old man with persistent PMT 1-year post-TAVR was managed successfully through radiofrequency catheter ablation. High-density 3-dimensional mapping identified a macro-reentrant circuit and a slow-conduction area adjacent to the transcatheter aortic valve implantation site, diagnosed as counterclockwise PMT. Ablation resulted in tachycardia termination, with no recurrence at follow-up. This case highlights structural alterations from TAVR as potential contributors to arrhythmic substrates. The rarity and successful management of PMT post-TAVR contribute significant insights, emphasizing the need for vigilant arrhythmic monitoring and tailored interventions. This case underscores the importance of recognizing and managing rare arrhythmic complications following TAVR, enhancing patient outcomes through precise diagnostic and interventional strategies.

本文言語英語
論文番号102967
ジャーナルJACC: Case Reports
巻30
号6P1
DOI
出版ステータス出版済み - 19 3月 2025

フィンガープリント

「Peri-Mitral Atrial Tachycardia Following Transcatheter Aortic Valve Replacement」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル