抄録
An improved method for inserting a silicone T tube through a tracheostomy stoma in patients with subglottic stenosis is presented. A silicone T tube is pulled into the trachea with a catheter that is inserted into the tracheostomy stoma, advanced through the stenotic subglottic space, and pulled out the mouth. A cone-shaped dilator is placed beforehand at the proximal end of the vertical limb of the T tube to facilitate the passage of that end through the stenotic subglottic space. This method was used in 4 patients with good results. We suggest this technique be tried when attempts to insert a T tube by the usual method fail, as it can be performed under local anesthesia without special instruments and is technically easy.
| 本文言語 | 英語 |
|---|---|
| ページ(範囲) | 327-329 |
| ページ数 | 3 |
| ジャーナル | Annals of Thoracic Surgery |
| 巻 | 51 |
| 号 | 2 |
| DOI | |
| 出版ステータス | 出版済み - 2月 1991 |
| 外部発表 | はい |