TY - JOUR
T1 - Variability in contrast and apparent diffusion coefficient of kiwifruit used as prostate MRI phantom
T2 - 1-week validation
AU - Hayashi, Tatsuya
AU - Yano, Shimpei
AU - Kojima, Shinya
AU - Ito, Toshimune
N1 - Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.
PY - 2022/12
Y1 - 2022/12
N2 - Kiwifruit has been proposed as a phantom for prostate magnetic resonance imaging (MRI) to adjust multiparametric MRI factors. This study evaluated the variability in contrasts and apparent diffusion coefficients (ADCs) via repeated scans of kiwifruits for 1 week. All scans were performed using a 3T MRI system. Six kiwifruits were prepared as phantoms. Each kiwifruit was scanned consecutively for 1 week, and T2-weighted and diffusion-weighted images were acquired. Contrasts between the peripheral placenta (PP) and central placenta (CP), and between the outer pericarp (OP) and CP were calculated. The ADCs of the PP, OP, and CP were also determined. The Friedman test with Scheffé’s post hoc comparison was used to assess contrast and ADC variability over 1 week; no significant differences between the contrasts or ADCs were found. Thus, each kiwifruit phantom exhibited low variability when used as a prostate MRI phantom.
AB - Kiwifruit has been proposed as a phantom for prostate magnetic resonance imaging (MRI) to adjust multiparametric MRI factors. This study evaluated the variability in contrasts and apparent diffusion coefficients (ADCs) via repeated scans of kiwifruits for 1 week. All scans were performed using a 3T MRI system. Six kiwifruits were prepared as phantoms. Each kiwifruit was scanned consecutively for 1 week, and T2-weighted and diffusion-weighted images were acquired. Contrasts between the peripheral placenta (PP) and central placenta (CP), and between the outer pericarp (OP) and CP were calculated. The ADCs of the PP, OP, and CP were also determined. The Friedman test with Scheffé’s post hoc comparison was used to assess contrast and ADC variability over 1 week; no significant differences between the contrasts or ADCs were found. Thus, each kiwifruit phantom exhibited low variability when used as a prostate MRI phantom.
KW - Multiparametric magnetic resonance imaging
KW - Phantom
KW - Prostate
UR - http://www.scopus.com/inward/record.url?scp=85137558833&partnerID=8YFLogxK
U2 - 10.1007/s12194-022-00677-z
DO - 10.1007/s12194-022-00677-z
M3 - 記事
C2 - 36065048
AN - SCOPUS:85137558833
SN - 1865-0333
VL - 15
SP - 424
EP - 429
JO - Radiological Physics and Technology
JF - Radiological Physics and Technology
IS - 4
ER -