Reproducibility of the ambulatory arterial stiffness index in hypertensive patients

  • Dirk G. Dechering
  • , Marijke S. Van Der Steen
  • , Ahmet Adiyaman
  • , Lutgarde Thijs
  • , Jaap Deinum
  • , Yan Li
  • , Eamon Dolan
  • , Reinier P.M. Akkermans
  • , Tom Richart
  • , Tine W. Hansen
  • , Masahiro Kikuya
  • , Jiguang Wang
  • , Eoin OBrien
  • , Theo Thien
  • , Jan A. Staessen

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Background: We studied the repeatability of the ambulatory arterial stiffness index (AASI), which can be computed from 24-h blood pressure (BP) recordings as unity minus the regression slope of diastolic on systolic BP. Methods: One hundred and fifty-two hypertensive outpatients recruited in Nijmegen (mean age = 46.2 years; 76.3% with systolic and diastolic hypertension) and 145 patients enrolled in the Systolic Hypertension in Europe (Syst-Eur) trial (71.0 years) underwent 24-h BP monitoring at a median interval of 8 and 31 days, respectively. We used the repeatability coefficient, which is twice the SD of the within-participant differences between repeat recordings, and expressed it as a percentage of four times the SD of the mean of the paired measurements. Results: Mean AASI (crude or derived by time-weighted or robust regression) and 24-h pulse pressure (PP) were similar on repeat recordings in both cohorts. In Nijmegen patients, repeatability coefficients of AASI and PP were ∼50%. In Syst-Eur trial patients, repeatability coefficient was ∼60% for AASI and ∼40% for PP. For comparison, repeatability coefficients for 24-h systolic and diastolic BP were ∼30%. Differences in AASI between paired recordings were correlated with differences in the goodness of fit (r) of the AASI regression line as well as with differences in the night-to-day BP ratio. However, in sensitivity analyses stratified for type of hypertension, r, or dipping status, repeatability coefficients for AASI did not widely depart from 50 to 60% range. Conclusion: Estimates of mean AASI were not different between repeat recordings, and repeatability coefficients were within the 50-60% range.

Original languageEnglish
Pages (from-to)1993-2000
Number of pages8
JournalJournal of Hypertension
Volume26
Issue number10
DOIs
StatePublished - Oct 2008
Externally publishedYes

Keywords

  • ambulatory arterial stiffness index
  • ambulatory blood pressure monitoring
  • arterial stiffness
  • diurnal blood pressure profile
  • reproducibility

Fingerprint

Dive into the research topics of 'Reproducibility of the ambulatory arterial stiffness index in hypertensive patients'. Together they form a unique fingerprint.

Cite this