Abstract
An anastomotic leak is one of the major complications following colorectal surgery. Standard treatments for anastomotic leak are total parenteral nutrition or temporary ileostomy. The over-the-scope-clipping (OTSC) system was originally developed to treat intestinal perforation or to close the tissue after natural orifice transluminal endoscopic surgery. Two cases of successful management of an anastomotic leak after colorectal surgery using the OTSC system are reported. One patient avoided a temporary ileostomy. In the other, hospitalization was shortened by the use of the OTSC system. The OTSC system can be a potential option in the management of anastomotic leaks after colorectal surgery.
| Original language | English |
|---|---|
| Pages (from-to) | 7984-7987 |
| Number of pages | 4 |
| Journal | World Journal of Gastroenterology |
| Volume | 20 |
| Issue number | 24 |
| DOIs | |
| State | Published - 2014 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Anastomotic leak
- Colorectal cancer
- Colorectal surgery
- Double stapling technique
- Over-the-scope-clipping
Fingerprint