TY - JOUR
T1 - Lung-protective properties of expiratory flow-initiated pressure-controlled inverse ratio ventilation
T2 - A randomised controlled trial
AU - Hirabayashi, Go
AU - Saito, Minami
AU - Terayama, Sachiko
AU - Akihisa, Yuki
AU - Maruyama, Koichi
AU - Andoh, Tomio
N1 - Publisher Copyright:
© 2020 Hirabayashi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2020/12
Y1 - 2020/12
N2 - Background Expiratory flow-initiated pressure-controlled inverse ratio ventilation (EF-initiated PC-IRV) reduces physiological dead space. We hypothesised that EF-initiated PC-IRV would be lung protective compared with volume-controlled ventilation (VCV). Methods Twenty-eight men undergoing robot-assisted laparoscopic radical prostatectomy were enrolled in this randomised controlled trial. The EF-initiated PC-IRV group (n = 14) used pressure-controlled ventilation with the volume guaranteed mode. The inspiratory to expiratory (I:E) ratio was individually adjusted by observing the expiratory flow-time wave. The VCV group (n = 14) used the volume control mode with a 1:2 I:E ratio. The Mann–Whitney U test was used to compare differences in the serum cytokine levels. Results There were no significant differences in serum IL-6 between the EF-initiated PC-IRV (median 34 pg ml-1 (IQR 20.5 to 63.5)) and VCV (31 pg ml-1 (24.5 to 59)) groups (P = 0.84). The physiological dead space rate (physiological dead space/expired tidal volume) was significantly reduced in the EF-initiated PC-IRV group as compared with that in the VCV group (0.31 ± 0.06 vs 0.4 ± 0.07; P<0.001). The physiological dead space rate was negatively correlated with the forced vital capacity (% predicted) in the VCV group (r = -0.85, P<0.001), but not in the EF-initiated PC-IRV group (r = 0.15, P = 0.62). Two patients in the VCV group had permissive hypercapnia with low forced vital capacity (% predicted). Conclusions There were no differences in the lung-protective properties between the two ventilatory strategies. However, EF-initiated PC-IRV reduced physiological dead space rate; thus, it may be useful for reducing the ventilatory volume that is necessary to maintain normocapnia in patients with low forced vital capacity (% predicted) during robot-assisted laparoscopic radical prostatectomy.
AB - Background Expiratory flow-initiated pressure-controlled inverse ratio ventilation (EF-initiated PC-IRV) reduces physiological dead space. We hypothesised that EF-initiated PC-IRV would be lung protective compared with volume-controlled ventilation (VCV). Methods Twenty-eight men undergoing robot-assisted laparoscopic radical prostatectomy were enrolled in this randomised controlled trial. The EF-initiated PC-IRV group (n = 14) used pressure-controlled ventilation with the volume guaranteed mode. The inspiratory to expiratory (I:E) ratio was individually adjusted by observing the expiratory flow-time wave. The VCV group (n = 14) used the volume control mode with a 1:2 I:E ratio. The Mann–Whitney U test was used to compare differences in the serum cytokine levels. Results There were no significant differences in serum IL-6 between the EF-initiated PC-IRV (median 34 pg ml-1 (IQR 20.5 to 63.5)) and VCV (31 pg ml-1 (24.5 to 59)) groups (P = 0.84). The physiological dead space rate (physiological dead space/expired tidal volume) was significantly reduced in the EF-initiated PC-IRV group as compared with that in the VCV group (0.31 ± 0.06 vs 0.4 ± 0.07; P<0.001). The physiological dead space rate was negatively correlated with the forced vital capacity (% predicted) in the VCV group (r = -0.85, P<0.001), but not in the EF-initiated PC-IRV group (r = 0.15, P = 0.62). Two patients in the VCV group had permissive hypercapnia with low forced vital capacity (% predicted). Conclusions There were no differences in the lung-protective properties between the two ventilatory strategies. However, EF-initiated PC-IRV reduced physiological dead space rate; thus, it may be useful for reducing the ventilatory volume that is necessary to maintain normocapnia in patients with low forced vital capacity (% predicted) during robot-assisted laparoscopic radical prostatectomy.
UR - http://www.scopus.com/inward/record.url?scp=85098133452&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0243971
DO - 10.1371/journal.pone.0243971
M3 - 記事
C2 - 33332454
AN - SCOPUS:85098133452
SN - 1932-6203
VL - 15
JO - PLoS ONE
JF - PLoS ONE
IS - 12
M1 - e0243971
ER -