Skip to main navigation Skip to search Skip to main content

Cylinder syringe suction: A simple and efficient technique for the evacuation of subcutaneous hematoma

  • Ayato Hayashi
  • , Norifumi Matsuda
  • , Masatoshi Horiguchi
  • , Takashi Matsumura
  • , Masakazu Komoto
  • , Yuhei Natori
  • , Yuzo Komuro
  • , Hiroshi Mizuno
  • Juntendo University

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

BACKGROUND: Subcutaneous hematoma is commonly caused by trauma or surgery. Proper treatment of the condition is needed to avoid severe complications. The present paper introduces a simple technique of hematoma evacuation, called cylinder syringe suction (CSS). Experiments were also performed to determine the detailed mechanism underlying its effectiveness. METHODS: The CSS procedure was performed as follows. A cylindrical plastic cylinder syringe was used. Either a few stitches were removed or a very small incision was made on the site of the hematoma. The edge of the syringe was compressed to the skin, which was covered by a thin hydrocolloid dressing. Vacuum aspiration was enforced at the site of the wound or incision, and the hematoma was gradually aspirated.For the experiment, house rabbits were used. Hematoma evacuation was performed in 4 different ways, including needle aspiration alone (group 1), needle puncture followed by CSS (group 2), and creation of a small wound (5 mm) followed by needle aspiration (group 3) or CSS (group 4). The amount of evacuated hematoma and the suction pressure created by each of the 4 methods were compared. RESULTS: Group 4 showed the highest suction pressure and the greatest evacuated amount of hematoma. High suction pressure was also obtained in group 1; however, the amount of evacuated hematoma was small as the other 2 groups. CONCLUSION: The CSS technique becomes effective mainly by creating high suction pressure, and the opening of a small wound enables the viscous coagula to pass through the skin.

Original languageEnglish
Pages (from-to)777-780
Number of pages4
JournalJournal of Craniofacial Surgery
Volume24
Issue number3
DOIs
StatePublished - May 2013
Externally publishedYes

Keywords

  • Aspiration
  • Hematoma
  • Hematoma evacuation
  • Subcutaneous hematoma
  • Syringe

Fingerprint

Dive into the research topics of 'Cylinder syringe suction: A simple and efficient technique for the evacuation of subcutaneous hematoma'. Together they form a unique fingerprint.

Cite this