TY - JOUR
T1 - Adhesion of Asian Dust Particles to Verofilcon a Soft Contact Lenses
AU - Mimura, Tatsuya
AU - Fujishima, Hiroshi
AU - Uchio, Eichi
AU - Fukagawa, Kazumi
AU - Kawashima, Makoto
AU - Kitsu, Kazuma
AU - Mizota, Atsushi
AU - Inoue, Yuji
N1 - Publisher Copyright:
© 2022 Mimura et al.
PY - 2022
Y1 - 2022
N2 - Purpose: Asian dust poses a serious global health hazard. Airborne particles adhering to contact lenses may cause substantial damage to the ocular surface. The recently released one-day disposable silicone hydrogel soft contact lens (SCL), the verofilcon A, has a smooth surface with SMARTSURFACE® technology, which is designed to prevent adhesion of protein components and foreign bodies. The purpose of this study was to verify the protective quality of verofilcon A SCL against adhesion of Asian dust particles to its surface. Methods: Verofilcon A and etafilcon A (control lens) SCLs were used (n=16 per group), and 0.2 mL of physiological saline containing 0.01 mg/mL of Asian dust particles was dropped on the surface of SCLs, allowed to stand for 1 hour, shaken for 1 minute, and rinsed three times with saline (after rinsing). In addition, the samples were agitated by a vortex mixer for 1 minute and rinsed three times with saline (after vortex). The number of Asian dust particles adhering to the SCLs and percentage of the surface area occupied by the Asian dust particles was determined before washing, after rinsing, and after vortexing. Results: The number of adherent Asian dust particles was lower on verofilcon A SCL (297 ± 116 after rinsing, and 5 ± 14 after vortexing) than on etafilcon A SCL (523 ± 212 after rinsing, p=0.003, and 378 ± 268 after vortexing, p<0.001). The Asian dust adhesion area was also lower on verofilcon A SCL (3.6 ± 2.3% after rinsing and 0.0 ± 0.1% after vortexing than on etafilcon A (10.2 ± 2.1% after rinsing, p=0.002, and 5.2 ± 3.0% after vortexing, p<0.001). Conclusion: These findings indicate that verofilcon A SCL has the property of low adhesion of Asian dust particles. Verofilcon A SCL can be recommended for SCL wearers during windy and Asian dust days.
AB - Purpose: Asian dust poses a serious global health hazard. Airborne particles adhering to contact lenses may cause substantial damage to the ocular surface. The recently released one-day disposable silicone hydrogel soft contact lens (SCL), the verofilcon A, has a smooth surface with SMARTSURFACE® technology, which is designed to prevent adhesion of protein components and foreign bodies. The purpose of this study was to verify the protective quality of verofilcon A SCL against adhesion of Asian dust particles to its surface. Methods: Verofilcon A and etafilcon A (control lens) SCLs were used (n=16 per group), and 0.2 mL of physiological saline containing 0.01 mg/mL of Asian dust particles was dropped on the surface of SCLs, allowed to stand for 1 hour, shaken for 1 minute, and rinsed three times with saline (after rinsing). In addition, the samples were agitated by a vortex mixer for 1 minute and rinsed three times with saline (after vortex). The number of Asian dust particles adhering to the SCLs and percentage of the surface area occupied by the Asian dust particles was determined before washing, after rinsing, and after vortexing. Results: The number of adherent Asian dust particles was lower on verofilcon A SCL (297 ± 116 after rinsing, and 5 ± 14 after vortexing) than on etafilcon A SCL (523 ± 212 after rinsing, p=0.003, and 378 ± 268 after vortexing, p<0.001). The Asian dust adhesion area was also lower on verofilcon A SCL (3.6 ± 2.3% after rinsing and 0.0 ± 0.1% after vortexing than on etafilcon A (10.2 ± 2.1% after rinsing, p=0.002, and 5.2 ± 3.0% after vortexing, p<0.001). Conclusion: These findings indicate that verofilcon A SCL has the property of low adhesion of Asian dust particles. Verofilcon A SCL can be recommended for SCL wearers during windy and Asian dust days.
KW - Asian dust
KW - daily soft contact lens
KW - etafilcon A
KW - silicone hydrogel
KW - verofilcon A
UR - http://www.scopus.com/inward/record.url?scp=85140839291&partnerID=8YFLogxK
U2 - 10.2147/OPTO.S381763
DO - 10.2147/OPTO.S381763
M3 - 記事
AN - SCOPUS:85140839291
SN - 1179-2752
VL - 14
SP - 215
EP - 221
JO - Clinical Optometry
JF - Clinical Optometry
ER -