Ablation characteristics and incidence of steam pops with a novel, surface temperature-controlled ablation system in an ex vivo experimental model

Kenta Tsutsui, Hitoshi Mori, Daisuke Kawano, Naomichi Tanaka, Yoshifumi Ikeda, Naokata Sumitomo, Shiro Iwanaga, Shintaro Nakano, Toshihiro Muramatsu, Kazuo Matsumoto, Ritsushi Kato

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: A novel irrigation catheter (QDOT MICRO™) has been introduced, which enables a surface temperature-controlled ablation combined with tip cooling. However, the detailed description of its complex behavior and effect on the incidence of pops and lesion formation remains elusive. This study aimed to systematically investigate the ablation characteristics, feedback behavior, and incidence of steam pops in a simplified ex vivo swine model. Methods: Using swine ventricular tissue perfused with saline at 37°C, we systematically created lesions with 4×3 combinations of the wattage (20, 30, 40, and 50 W) and contact force (CF, 10, 30, and 50 g). Ablation was continued for either 120 s or until a steam pop occurred and repeated 10 times with each setting. The lesion geometry, ablation index, feedback dynamics, and conditions underlying the steam pops were measured and analyzed. Results: Steam pops occurred particularly frequently in combinations of a low CF and high power (10 g vs. 30 g+50 g [p <.0001]; 40 W+50 W vs. 20 W+30 W [p <.0001]). Failure to activate a feedback process was associated with a 5.1 times higher incidence of steam pops (21/109 vs.11/11, [95% CI 3.499–7.716], p <.0001). The wattage feedback was particularly evident with a high CF (30 and 50 g) and high initial wattage (40 and 50 W). The average delivered wattage at 27 W predicted the occurrence of steam pops. Conclusion: The temperature-controlled ablation with the QDOT MICRO™ demonstrated a complex feedback behavior, which contributed to a reduced incidence of steam pops and prolonged lead time to the pops.

Original languageEnglish
Pages (from-to)1390-1400
Number of pages11
JournalPACE - Pacing and Clinical Electrophysiology
Volume45
Issue number12
DOIs
StatePublished - Dec 2022
Externally publishedYes

Keywords

  • ex vivo experiment
  • lesion size
  • radiofrequency ablation
  • steam pop
  • surface temperature control

Fingerprint

Dive into the research topics of 'Ablation characteristics and incidence of steam pops with a novel, surface temperature-controlled ablation system in an ex vivo experimental model'. Together they form a unique fingerprint.

Cite this